Representative image of family GA01-3
Anti-pull-out double-chamber flange adaptor
Restrained double-chamber flange adaptor DN 110
Ref. BDA60110DN 110In stock
Self-restrained double-chamber flange adaptor for a secure connection between PVC/PE pipes and flanged components (valves, pumps, etc.). Made of GGG-50 ductile iron, it eliminates the need for thrust blocks, saving installation time and costs.
- Nominal diameter
- DN 110
- Family
- GA01-3 · Anti-pull-out double-chamber flange adaptor
- ERP description
- B.D.CAMARA F.D.AUTOB.DN 110 GA
- Body and flange: High-strength EN-GJS-500-7 (GGG-50) ductile iron.
- Locking system: MS-58 brass grip ring.
- Sealing gasket: EPDM rubber, certified for drinking water use.
- Coating: Electrostatically applied epoxy paint with a minimum thickness of 250 microns, guaranteeing superior corrosion protection.
- Nominal pressure (PN): 16 bar.
- Flange drilling: To UNE-EN 1092-2 PN16, ensuring compatibility with all standard components on the market.
- Compatible pipes: PVC and high-density polyethylene (HDPE).
Other anti-pull-out double-chamber flange adaptor sizes
All references- BDA60063Restrained double-chamber flange adaptor DN 50/63In stock
- BDA60075Restrained double-chamber flange adaptor DN 75In stock
- BDA60090Restrained double-chamber flange adaptor DN 90In stock
- BDA60125Restrained double-chamber flange adaptor DN 125Last units
- BDA60140Restrained double-chamber flange adaptor DN 140In stock
- BDA60160Restrained double-chamber flange adaptor DN 160In stock
From the blog: guides on this family
More news
10 March 2026Universal, wide-range or anti-pull flange adaptor: which to choose to connect pipe to a valveAll three go from plain pipe to flange, but they solve different problems: diameter tolerance, transition between materials or axial restraint. A short guide so you do not order the wrong part.
19 August 2026How to repair a leak in a buried PVC pipe without stopping irrigationAnti-pull repair collar or stainless steel repair clamp: which to use depending on the type of break, how it is fitted in the trench and why the repair withstands the pressure of the irrigation season.
28 April 2026How to connect an asbestos cement pipe to PVC or HDPE without replacing the whole networkThousands of kilometres of asbestos cement pipe are still in service. When you have to join it to new pipe, the right part depends on the outside diameters and on whether there is a risk of pull-out: Gibault joint, wide-range coupling or self-anchoring transition coupling.